The Autorodder Eliminates Spurious Shut Downs and Unplanned Outages

The Autorodder Eliminates Spurious Shut Downs and Unplanned Outages

Prior to utilizing Clearguard Autorodders, technicians would have to manually rod-out and blow down 60 DP level instrument measurement tapping points every day across the three finishing towers of the acrylic acid unit at BASF Freeport.

This potentially hazardous task required at least two technicians to climb up the 9 levels in full PPE to undertake the tasks.

Each of BASF Freeports custom manufactured Autorodder feature a 1” ANDI 150# process connection, 32mm diameter cylinder, 400mm stroke Inconel shaft and “scraper” tip that ensures true and accurate readings 24/7.

The Clearguard Autorodders at Freeport are all controlled by UL “Hazloc” certified Class 1, Division 2 hazardous area classification control solutions, that include ASCO solenoid valves, integral timer modules to control the stroke frequency, and local and remote position indication in the DCS.

Since the first installation, there have been no pressure spikes, spurious outages, manual rod-out or blow downs. Each Clearguard Autorodder installation is saving BASF 3,000 USD per month resulting in an ROI in under four months.

For further details, please contact Ben Cammack, VP Global Operations for Clearguard ben.c@clearguard.com .

Click here for more informationClick here for related articles and news

Clearguard Pty Ltd is an innovative engineering solutions provider. We are about providing systems and services tailored to our client’s requirements. Our scope of operations includes the provision of automatic process, instrument and maintenance engineering solutions. As an organisation, we see our future intricately linked to the communities …

More in Level Control and Measurement

Source of Article